Solar power inverter with PWM Solar charger 7KW - 20KW for Villa/ office

DESCRIPTION

Heavy duty pure sine wave inverter 7KW - 20KW LSI series 

Main features:

1. 2 times peak power, excellent loading capability
2. Bulit-in AVR stablizer. supply the continuous stable outpout.
3. Built-in PWM solar charging controller
4. Working efficiency more than 85%
5. Tranfer time ≤ 10ms
6. LCD display with multi-function buttons.
7. Pure sine wave output wave form, input and output isolation design
8. Intelligent fan (Automatically adjust rotating speed according to the internal temperature)
9. Perfect protection against low voltage, over voltage, short circuit, over load and over temperature etc.

 

Technical specs

Model LSI-702 LSI-103 LSI-153 LSI-203
Rated Power 7KW 10KW 15KW 20KW
Peak Power 21KW 30KW 45KW 60KW
Nominal battery voltage 96VDC 192VDC
Input DC input range 84-120VDC (96V) / 168-240VDC (192V)
AC Mains input range (220/230/240VAC) 140-275VAC 170-250VAC
AC input frequency 50Hz: 45-65Hz / 60Hz: 55-65Hz (50Hz/60Hz automatic recognition)
Protection Low battery alarm ≤84VDC (96V) / ≤168VDC (192V) alarm
Low battery protection ≤80VDC (96V) / ≤160VDC (192V) automatic shutdown
High battery alarm ≥120VDC (96V) / ≥240VDC (192V) alarm
High battery protection ≥136VDC (96V) / ≥272VDC (192V) automatic shutdown
Over load protection 110% more than rated capacity, automatic shutdown
High temperature Built-in temperature real time sensor, ≥85℃ alarm, ≥90℃ automatic shutdown
Short circuit protection Automatic shutdown
Output Transfer efficiency ≥85%
Output voltage (DC battery mode) 220/230/240VAC±2%
Output frequency (DC battery mode) 60/50Hz±1%
Output wave form Pure sine wave
Output voltage (AC mains mode) stable 220/230/240VAC±10% output (built-in AVR stablizer)
AVR output stablizer AC mains<140VAC±5% swtich to DC battery mode, AC mains>150VAC ±5% return to AC mains mode;
AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC ±5% return to AC mains mode;
The above is for output 220V system reference, 230V/240V output just multiply by percentage
Output frequency (AC mains mode) automatic tracing from AC input
Other Transfer time Bult- in AC bypass replay (≤4ms)
Display LCD Display with function buttons
Cooling system Intelligent cooling fan control system
≤42℃ slow fan, ≥45℃ fast fan
AC Charger AC charging Voltage /108.8-113.6VDC(96V)/217.6-227.2VDC(192V)
AC charging current Steady 15A
AC over charge protection Battery ≧128V (96V) ≧256V (192V), stop charging after 60s alarm
Working mode optional 01 AC mains priority
Always use AC mains as priority input to provide AC output and automatically charge the battery
stops charging when battery is fully charged, and only starts DC to AC converting untill AC mains is off
02 Energy saving
Loading≤10% automatic shutdown, loading≥11%-100% automatic turn on
03 DC battery priority
Always use DC battery as priority input to provide AC output, for 12V system, when battery≥13V,
starts DC to AC converting; when battery≤84V during converting, switch to AC mains mode to provide AC output and
when battery≤84V during converting, switch to AC mains mode to provide AC output and
Comnunication RS-232/USB/SNMP(additional option)
Environment Temperature -20~+75℃
Humidity <95%
PWM Solar Controller specification Charging & discharging 100A
Max. PV input voltage Max. 200V (96V) / 400V (192V)
System voltage 96V / 192V
No load current <5mA
Charging circuit drop ≤0.2V
Discharging circuit drop ≤0.15V
Over charge protection 136V (96V) / 272V (192V) stop charging
Boost charging 116.8V (96V) / 233.6V (192V) Duration: 30mins
Direct charging 115.2V (96V) / 230.4V (192V) Duration: 30mins
Float charging 108.8V (96V) / 217.6V (192V) until reach charging recovery voltage
Charging recovery 110.4V (96V) / 220.8V (192V)
Over discharging recovery 100V (96V) / 200V (192V)
Low voltage 84V (96V) / 168V (192V) alarm
Over discharging 80V (96V) / 160V (192V) automatic shutdown
Temperature compensation -4.0mv/℃/2V(Boost charging, Direct charging, float charging and charging recover voltage compensation)
Control method PWM smart charging
Working temperature -20~+75℃
Circuit protection Over charging, over discharging, overload and short circuit protection

All protections are harmless to any parts and fuse of controller;

fuse is only for ultimate protection.

Anti connection-reverse protection for solar panel
Appearance Product size (mm) 485*300*655mm
Packing size (mm) 623*385*709mm
Net Weight (kg) 58kg 86.5kg 106.5kg 126.5kg
Gross Weight (kg) 73kg 101.5kg 121.5kg 141.5kg